Design and Implementation of Electrocardiogram Signal Monitoring System Using Electrode Sensors
DOI:
https://doi.org/10.59890/ijist.v4i11.84Keywords:
Electrocardiogram (ECG); Electrode Sensor; Arduino Atmega 2560; Real Time Monitoring; Signal Acquisition.Abstract
This study aims to design and create a system that can monitor electrocardiogram (ECG) signals using electrodes and an Arduino ATmega 2560. This system captures electrical signals from heart activity, processes the obtained data, and displays the results directly (in real time) on a computer screen. With this system, the shape and changes of ECG signals can be more easily observed, helping users understand the characteristics of heart signals. Test results show that the system successfully records the ECG Lead I signal with a sampling frequency of 360 Hz. Placing the electrode on the chest produces a signal with an amplitude of 200 mV, while placing on the hand produces 1030 mV. This difference indicates that the electrode position affects the measurement results, including the level of interference in the signal. The digital filter consisting of high-pass, low-pass, and notch is able to reduce noise in the ECG signal, with an average processing time of 405 μs. The developed GUI is capable of displaying ECG signals with an average error of 0.52%. The system also demonstrates data consistency over 7 days of testing.
References
Clifford, G. D., Azuaje, F., & McSharry, P. E. (2006). Advanced Methods and Tools for ECG Data Analysis. Artech House.
Webster, J. G. (Ed.). (2009). Medical Instrumentation: Application and Design. 4th ed. John Wiley & Sons.
Rangayyan, R. M. (2015). Biomedical Signal Analysis: A Case-Study Approach. 2nd ed. Wiley-IEEE Press.
Tompkins, W. J. (1993). Biomedical Digital Signal Processing: C-Language Examples and Laboratory Experiments for the IBM PC. Prentice Hall.
Levkov, C., Mihov, G., Ivanov, R., Daskalov, I., Christov, I., & Dotsinsky, I. (2005). Removal of power-line interference from the ECG: A review of the subtraction procedure. Biomedical Engineering Online, 4, 50.
McManus, C. D., Neubert, K. D., & Cramer, E. (1993). Characterization and elimination of AC noise in electrocardiograms: A comparison of digital filtering methods. Computers and Biomedical Research, 26(1), 48–67.
Moody, G. B., & Mark, R. G. (2001). The impact of the MIT-BIH Arrhythmia Database. IEEE Engineering in Medicine and Biology Magazine, 20(3), 45–50.
Goldberger, A. L., et al. (2000). PhysioBank, PhysioToolkit, and PhysioNet: Components of a new research resource for complex physiologic signals. Circulation, 101(23), e215–e220.